Spectro UV-VIS Double PC 8 Auto Cell
Scanning Spectrophotometer
UV-VIS Double Beam
Model UVD-3000

Spectro UV-Vis Double PC 8 Auto and 1 Fixed Cell (Model UVD-3000) is a high performance UV-Vis double beam automatic scanning spectrophotometer.  It is an automatic eight (8) cell spectrophotometer for precise testing with a fixed bandwidth of 2.0 nm.  Model UVD-3000 spectrophotometer offers high performance, ease of use and reliability, which can be used in various applications. Spectrophotometer Model UVD-3000 can be used extensively for qualitative and quantitative analysis in such fields as pharmaceutical inspection, clinical analysis, petrochemistry laboratories, chemistry and biochemistry laboratories, DNA/RNA analysis as well as in quality control departments, i.e. environmental control, water management, food processing, and agriculture.

Spectro UV-Vis Double PC 8 Auto Cell (Model UVD-3000) utilizes a new optical system design and is microcomputer controlled.  With its focused-beam design, the system provides optimal and reproducible results for small samples.  The sample beam and the reference beam are provided within the same sampling space which in turn facilitates wider and longer scan of data providing a more detailed view of the results in an easy to use environment.  This instrument has excellent baseline stability and high resolution and permits scanning, quantitative analysis, kinetic spectrophotometric analysis and DNA/RNA analysis through PC control.  This product is capable of processing data, from analytical and spectrum testing.
Spectro UV-Vis Double PC 8 Auto Cell (Model UVD-3000) has a large LCD screen which displays the menu screen and of course makes the device easier to use.  Additionally, this instrument has a powerful built in software which permits the apparatus to be linked to a computer and a printer to display the photometric and spectral data on the PC monitor. 
Labomed, Inc. is certified by
ISO 9001-2000, has CE Conformity and is FDA Licensed.

 

Spectro UV-Vis Double PC 8 Auto Cell (Model UVD-3000)
with fixed bandwidth of 2.0 nm
is a high-performance, reliable, and exceptional value instrument
which is the hallmark of Labomed UV-Vis spectrophotometers.
There are 2 models of Spectro UV-VIS Double PC 8 Auto Cell available to the public:

1) Model UVD-3000 Spectro UV-VIS Double PC 8 Auto Cell with fixed bandwidth of 2 nm.
2) Model UVD-3200 Spectro UV-VIS Double PC 8 Auto Cell with variable bandwidth of 0.5, 1.0, 2.0 & 5.0 nm

Features

Top of the Page

  • Baseline Stability: The Double beam monitoring ratio system enhances baseline stability.

  • Excellent Resolution: The big-caliber light path enhances the instrument’s energy, reduces its noise and raises its resolution performance

  • Automatic successive measurement: The automatic eight-cell sample holder offers the automatic measurement of eight samples in succession. So it can bring about one-touch measurement of the solution of six samples and a blank.

  • User-friendly light source: The socket deuterium lamps and tungsten lamps facilitate light source replacement, simplify maintenance and reduce operation error.

  • Convenient Display: The large backlit LCD screen displays both photometric values and spectral curves.

  • Full use of Computer Technology: Being computer controlled with RS-232 interface and working on the Windows platform with the UV/Win application software.

  • The key components adopt all from the world famous manufacturer, such as deuterium lamp, silicon photodiode and holographic grating, which ensures the stabilization and credibility of the Instrument for extended life.

  • Computer System is optional (NOT INCLUDED).

Software Specifications

Monoprocessor Built-in Application:

  • Photometric Measurement: Measuring transmittance or absorbance at the current wavelength together with K factor calculations.

  • Spectrum Scan: Carrying out scanning of transmittance or absorbance on the selected wavelength range together with peak-pick module.

  • Quantitative Determination: Regression of standard curves and direct determination concentration of samples.
PC Windows Application Software (RS-232 Interface) to link Spectro to computer and printer:
  • Photometric Measurement: Measuring the photometric values at 1-10 wavelengths together with mathematical calculations according to entered quotations.
  • Spectrum Scan: Producing wavelength scans within the operating parameters on samples together with powerful data handling facilities.
  • Quantitative Determination: Determination of unknown concentration with methods of 1-3 wavelength quantitation, together with fitting of calibration curve of 1st ~ 4th order.
  • Kinetics: Recording curves of changing photometric values of samples against timecourse at the selected wavelengths together with powerful data handling facilities.
  • Output: With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports.

 

Included Accessories

Top of the Page

  • 8 Auto Cell Holder

  • 8 Optical Glass Cells 10mm.

  • 2 Quartz Cells 10mm.

  • 1 Dust cover

  • 1 Instruction manual

  • 1 Power cable

  • 1 PC cable

  • 1 Software CD for Windows 98/2000/XP

  • 1 Software Operation Manual

  • 1 Spare Tungsten Halogen Lamp

  • 1 Block Light Cell

  • 1 Extra fuse

Optional Accessories

  • Set of 2 performance testing filters (1 "E filter" for photometric accuracy test and 1 didymium filter for wavelength accuracy test)

  • Peltier constant temperature system (15 - 55ºC Specify: SpectroUV-Vis Double PC 8 Auto Cell)

  • Sipper flow through system (Peristaltic pump and flowcell. Specify: Spectro UV-Vis Double PC 8 Auto Cell)

  • Multi purpose cell holder for long path cells, 20 - 50mm path length
    (Specify: Spectro UV-Vis Double PC 8 Auto Cell)

Top of the Page

Technical Specifications

Top of the Page
|

Features

Top of the Page

  • Baseline Stability: The Double beam monitoring ratio system enhances baseline stability.

  • Excellent Resolution: The big-caliber light path enhances the instrument’s energy, reduces its noise and raises its resolution performance

  • Automatic successive measurement: The automatic eight-cell sample holder offers the automatic measurement of eight samples in succession. So it can bring about one-touch measurement of the solution of six samples and a blank.

  • User-friendly light source: The socket deuterium lamps and tungsten lamps facilitate light source replacement, simplify maintenance and reduce operation error.

  • Convenient Display: The large backlit LCD screen displays both photometric values and spectral curves.

  • Full use of Computer Technology: Being computer controlled with RS-232 interface and working on the Windows platform with the UV/Win application software.

  • The key components adopt all from the world famous manufacturer, such as deuterium lamp, silicon photodiode and holographic grating, which ensures the stabilization and credibility of the Instrument for extended life.

  • Computer System is optional (NOT INCLUDED).

Software Specifications

Monoprocessor Built-in Application:

  • Photometric Measurement: Measuring transmittance or absorbance at the current wavelength together with K factor calculations.

  • Spectrum Scan: Carrying out scanning of transmittance or absorbance on the selected wavelength range together with peak-pick module.
  • Quantitative Determination: Regression of standard curves and direct determination concentration of samples.
PC Windows Application Software (RS-232 Interface) to link Spectro to computer and printer:
  • Photometric Measurement: Measuring the photometric values at 1-10 wavelengths together with mathematical calculations according to entered quotations.
  • Spectrum Scan: Producing wavelength scans within the operating parameters on samples together with powerful data handling facilities.
  • Quantitative Determination: Determination of unknown concentration with methods of 1-3 wavelength quantitation, together with fitting of calibration curve of 1st ~ 4th order.
  • Kinetics: Recording curves of changing photometric values of samples against timecourse at the selected wavelengths together with powerful data handling facilities.
  • Output: With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports.

 

Included Accessories

Top of the Page

  • 8 Auto Cell Holder

  • 8 Optical Glass Cells 10mm.

  • 2 Quartz Cells 10mm.

  • 1 Dust cover

  • 1 Instruction manual

  • 1 Power cable

  • 1 PC cable

  • 1 Software CD for Windows 98/2000/XP

  • 1 Software Operation Manual

  • 1 Spare Tungsten Halogen Lamp

  • 1 Block Light Cell

  • 1 Extra fuse

Optional Accessories

  • Set of 2 performance testing filters (1 "E filter" for photometric accuracy test and 1 didymium filter for wavelength accuracy test)

  • Peltier constant temperature system (15 - 55ºC Specify: SpectroUV-Vis Double PC 8 Auto Cell)

  • Sipper flow through system (Peristaltic pump and flowcell. Specify: Spectro UV-Vis Double PC 8 Auto Cell)

  • Multi purpose cell holder for long path cells, 20 - 50mm path length
    (Specify: Spectro UV-Vis Double PC 8 Auto Cell)

Top of the Page

Technical Specifications

Top of the Page
|

Features

Top of the Page

  • Baseline Stability: The Double beam monitoring ratio system enhances baseline stability.

  • Excellent Resolution: The big-caliber light path enhances the instrument’s energy, reduces its noise and raises its resolution performance

  • Automatic successive measurement: The automatic eight-cell sample holder offers the automatic measurement of eight samples in succession. So it can bring about one-touch measurement of the solution of six samples and a blank.

  • User-friendly light source: The socket deuterium lamps and tungsten lamps facilitate light source replacement, simplify maintenance and reduce operation error.

  • Convenient Display: The large backlit LCD screen displays both photometric values and spectral curves.

  • Full use of Computer Technology: Being computer controlled with RS-232 interface and working on the Windows platform with the UV/Win application software.

  • The key components adopt all from the world famous manufacturer, such as deuterium lamp, silicon photodiode and holographic grating, which ensures the stabilization and credibility of the Instrument for extended life.

  • Computer System is optional (NOT INCLUDED).

Software Specifications

Monoprocessor Built-in Application:

  • Photometric Measurement: Measuring transmittance or absorbance at the current wavelength together with K factor calculations.

  • Spectrum Scan: Carrying out scanning of transmittance or absorbance on the selected wavelength range together with peak-pick module.

  • Quantitative Determination: Regression of standard curves and direct determination concentration of samples.
PC Windows Application Software (RS-232 Interface) to link Spectro to computer and printer:
  • Photometric Measurement: Measuring the photometric values at 1-10 wavelengths together with mathematical calculations according to entered quotations.
  • Spectrum Scan: Producing wavelength scans within the operating parameters on samples together with powerful data handling facilities.
  • Quantitative Determination: Determination of unknown concentration with methods of 1-3 wavelength quantitation, together with fitting of calibration curve of 1st ~ 4th order.
  • Kinetics: Recording curves of changing photometric values of samples against timecourse at the selected wavelengths together with powerful data handling facilities.
  • Output: With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports.

 

Included Accessories

Top of the Page

  • 8 Auto Cell Holder

  • 8 Optical Glass Cells 10mm.

  • 2 Quartz Cells 10mm.

  • 1 Dust cover

  • 1 Instruction manual

  • 1 Power cable

  • 1 PC cable

  • 1 Software CD for Windows 98/2000/XP

  • 1 Software Operation Manual

  • 1 Spare Tungsten Halogen Lamp

  • 1 Block Light Cell

  • 1 Extra fuse

Optional Accessories

  • Set of 2 performance testing filters (1 "E filter" for photometric accuracy test and 1 didymium filter for wavelength accuracy test)

  • Peltier constant temperature system (15 - 55ºC Specify: SpectroUV-Vis Double PC 8 Auto Cell)

  • Sipper flow through system (Peristaltic pump and flowcell. Specify: Spectro UV-Vis Double PC 8 Auto Cell)

  • Multi purpose cell holder for long path cells, 20 - 50mm path length
    (Specify: Spectro UV-Vis Double PC 8 Auto Cell)

Top of the Page

Technical Specifications

Top of the Page

1) Wavelength range: 190 nm – 1100 nm
- Spectral bandwidth: 2.0 nm (Model UVD-3000 ) and 0.5, 1.0, 2.0 and 5.0 nm.(Model UVD-3200)
- Resolution: 2nm. (UVD-3000) and 0.5nm. (UVD-3200)
- Stray Light: <0.2%T (220 nm, Nal; 340 NaNo2), >=2.0Abs (KCI, 200nm)
- Wavelength accuracy: 0.3nm
- Wavelength Reproducibility: 0.2 nm
2) Photometric System: The double-beam monitoring ratio system.
- Photometric Method: Transmittance, absorbance, energy and concentration
- Photometric Range: -0.3~3.0 Abs
- Photometric Accuracy: 0.002Abs (0~0.5A)
0.004Abs (0.5~1A)
0.3%T (0~100%T)
- Photometric Reproducibility: 0.001Abs (0~0.5A)
0.002Abs (0.5~1A)
0.15%T (0~100%T)
- Photometric Display: -9999 ---- 9999
- Photometric Noise: 0.001Abs (500nm, 0Abs 2nm Spectral Bandwidth).
- Scanning Speed: 1400nm/min
- Baseline flatness:
0.0015 Abs (190-1100nm)
- Baseline stability: 0.008Abs/h (500nm, 0Abs 2nm Spectral Bandwidth, 2Hr. warm-up)
- Slew rate of wavelength: 3600nm/min
3) DNA/RNA Measurement:  
- Results Printout:
Printing of measured data by using any Printer with Parallel Port connection available.
4) Mainframe: Compact and standalone spectrophotometer mainframe
- Light Source: Socket Deuterium Lamp and Socket Tungsten Halogen Lamp.
- Detector: Double Beam
- Sample Chamber: Automatic eight-cell sample holder.
- Display Liquid Crystal Display (LCD 320 iÀ240 dot matrix)
- Keypad: Touch soft keys.
- PC Interface: PC Interface: RS-232
- Size: 22x16x10”
- Weight: 55 Lb

Information Request Form

Top of the Page

Select the items that apply, and then let us know how to contact you.

Send product literature
Send company literature
Have a distributor contact me

Full Name
Title
Company
Website
Address

Please make sure to write your complete address. Include State or Province, ZIP code and Country.

E-mail
Phone
Fax

 

 

 

 

 

 


Print Brochures in PDF! Click Here

2921 S La Cienega Blvd. Suite A

Culver City, CA 90232 U.S.A

TEL (310) 202-0814  FAX (310) 202-7286

Email: spectro@labomed.com

Send mail to Company Webmaster with questions or comments about this web site.
Copyright © 2010